Figure 8: Two graphs showing results of RE102 Radiated Emissions testing before and after installing an EESeal. Attenuation of 5-10dB was needed at numerous frequencies over a wide range. The problem was solved with a filter containing several capacitors in parallel on each pin ranging from 47 p F to 2 Mu F.