MDM Insertion Tool Instructions
EESeal® Insertion Instructions for Micro-D & MDM Connectors
The very high density of MDM Style EESeals® and potential cutting action of the MDM connector’s sockets make installation by hand more difficult than our standard EESeals®. As a result, Quell has developed MDM Installation Tools to ensure that your EESeal® is installed easily and reliably into your MDM connector. Please follow these instructions carefully and take your time. It is recommended that you watch the easy to follow installation video showing you the easy step by step instructions.
Printable Installation Instructions for Micro-D & MDM Connectors
Not the right connector type? View Instructions for Circular Connectors or DSub Connectors.
Step 1: Insert Guide Pins
Begin by inserting the MDM insertion tool into your connector. Squeeze the tool to release the guide pins into the MDM sockets. Be careful to keep the MDM pins face up to keep the guide pins in place.

Step 2: Orient the EESeal®
Arrange the EESeal® so the blank side is up and the side with the EESeal® logo is down, and the shape of the EESeal® matches up to the shape of the connector.
Important Note: It is imperative that the EESeal® be inserted “right side up” (with the EESeal® logo down and no printing visible after it’s inserted). The MDM connector is symmetrical about the vertical centerline and, thus, if an EESeal® is incorrectly inserted with the EESeal® logo up, it will not filter the correct pins.

Step 3: Initial EESeal® Placement
Place the EESeal® over the guide pins until the guide pins protrude through the holes of the EESeal®. Use the insertion block to press the EESeal® down over the guide pins. The insertion block helps to maintain even downward pressure across the EESeal®. The EESeal® should now be in place just above the rim of the MDM.

Step 4: Seating the EESeal®
Gently press the edges of the EESeal® below the connector rim using your finger or a soft tool. To complete installation, use the MDM tool to seat the EESeal® at the bottom of the connector and extract the guide pins from the MDM connector and back into the tool.

Your MDM is Now a Filtered MDM Connector

Extraction
MDM style EESeals®cannot be extracted without damaging the EESeal®. Use any dull probe to carefully reach under the inserted EESeal® and slowly work it out. Slowly work it up the shaft of all sockets a little bit at a time, working around the perimeter. Do not try to pry the EESeal® completely off some sockets when other sockets are still fully seated. Slowly working the EESeal® out will minimize tearing and make it easier to get it out in one piece without leaving torn sections behind.
Questions?
Please call (505) 243-1423 or email EESeal@Quell.US for help.